VA-FA Pipettes
Ergonomic & Light Weight Design

Ergonomic & Light Weight Design
for Easy Usage

Durable Tip Cone Made Of PVDF

Durable Tip Cone Made Of PVDF
Offers highest resistance to physical and chemical corrosion.

Tip Ejector

Tip Ejector
Smooth One-hand Ejection To Prevent Any Contamination*

Two Step Plunger

Two Step Plunger
Allows Forward & Reverse Pipetting Technique

Semi Autoclavable

Semi Autoclavable
Comes With Autoclavable Lower Assembly

Error Free Volume Setting

Error Free Volume Setting
Ensures Accurate Dispensing Of The Liquid

Features Read More
  • Comfortable finger rest for both right and left hand usage
  • Ideal shaft shape for reaching into narrow/deep tubes
  • Each pipette calibrated as per ISO 8655-6 standards at our ISO 17025 accredited lab and supplied with individual calibration certificate
  • Comes with an autoclavable lower assembly
  • Attractive color coding for easy volume identification.
  • Compatible with a wide range of tips
Multichannel Pipette Read More

Accumax VA-FA Multichannel Pipette

Includes All Basics Features of Accumax VA-FA Single Channel & Additional Features Like

  • Soft force & leak free tip loading and ejection.
  • All internal components in the manifold are made of high-quality alloys produced by fine tooling to deliver precise volume across all channels
  • Easily removable manifold for convenient maintenance
  • 360° rotatable manifold for effortless and flexible pipetting
  • One hand tip ejection.
  • Attractive color coding for easy volume identification
  • Compatible with most types of tips
Pipette Stand Read More
CAT NO. Description
SA-100
Accumax VA-FA Pipette
SA-200
Ordering Information & Technical Specification Read More

Variable Volume Pipettes

Cat. No. Volume Range [µl] Increments [µl] Test Volume [µl] Inaccuracy (±) % Inaccuracy (±) µl Imprecision(±) % Imprecision(±) µl
VA-100
0.5-10 µl
0.1
1
2.5
0.03
1.5
0.02
5
2
0.10
1
0.05
10
1
0.10
0.8
0.08
VA-125
0.1 – 2.5 µl
0.01
0.25
12
0.03
6
0.02
1.25
3
0.04
3
0.04
2.5
2.5
0.06
1.6
0.04
VA-200
5-50 µl
0.5
5
2
0.10
2
0.10
25
0.8
0.20
0.4
0.10
50
0.6
0.3
0.3
0.15
VA-300
50-200 µl
1
50
1
0.50
0.4
0.20
100
0.8
0.80
0.2
0.20
200
0.60
1.20
0.15
0.30
VA-400
200-1000 µl
5
200
0.9
1.80
0.3
0.6
500
0.75
3.75
0.25
1.25
1000
0.60
6.00
0.2
2.00
VA-500
10-100 µl
0.5
10
3
0.30
1.5
0.15
50
1
0.5
0.5
0.25
100
0.8
0.80
0.15
0.15
VA-600
100-1000 µl
5
100
2
2.00
0.7
0.70
500
1
5.00
0.4
2.00
1000
0.6
6.00
0.2
2.00
VA-700
2-20 µl
0.1
2
3
0.06
2
0.04
10
1.5
0.15
1
0.10
20
0.9
0.18
0.4
0.08
VA-800
20-200 µl
1
20
2
0.4
0.8
0.16
100
0.7
0.70
0.3
0.30
200
0.6
1.20
0.15
0.30
VA-900
1000-5000 µl
50
1000
0.8
8.00
0.3
3.00
2500
0.6
15.00
0.2
5.00
5000
0.5
25.00
0.15
7.50
VA-905
500-5000 µl
50
500
2
10.00
0.6
3.00
2500
0.6
15.00
0.3
7.50
5000
0.5
25.00
0.15
7.50
VA-1000
1000-10000 µl
100
1000
3
30.00
0.6
6.00
5000
1.2
60.00
0.30
15.00
10000
0.60
60.00
0.2
20.00
VA-1005
500-10000 µl
100
1000
3
30.00
0.6
6.00
5000
1.2
60.00
0.30
15.00
10000
0.60
60.00
0.2
20.00

Fix Volume Pipettes

Cat. No. Volume Range [µl] Test Volume [µl] Inaccuracy (±) % Inaccuracy (±) µl % Imprecision(±) % Imprecision(±) µl%
FA-205
2.5 µl
2.5
2
0.05
1.6
0.04
FA-5
5 µl
5
1.3
0.07
1.2
0.06
FA-10
10 µl
10
0.8
0.08
0.8
0.08
FA-20
20 µl
20
0.6
0.12
0.5
0.10
FA-25
25 µl
25
0.5
0.13
0.3
0.08
FA-50
50 µl
50
0.5
0.25
0.3
0.15
FA-100
100 µl
100
0.5
0.50
0.3
0.30
FA-200
200 µl
200
0.4
0.80
0.2
0.40
FA-250
250 µl
250
0.4
1.00
0.2
0.50
FA-500
500 µl
500
0.3
1.50
0.2
1.00
FA-1000
1000 µl
1000
0.3
3.00
0.2
2.00
FA-2000
2000 µl
2000
0.3
6.00
0.15
0.03
FA-5000
5000 µl
5000
0.3
15.00
0.15
7.50
FA-10000
10000 µl
10000
0.6
60.00
0.2
0.20

Accumax VA-FA (Multi 8 Channel)

Cat. No. Volume Range [µl] Increments [µl] Test Volume [µl] Inaccuracy (±) % Inaccuracy (±) µl % Imprecision(±) % Imprecision(±) µl%
MA8-010
0.5-10 µl
0.1
10
1.5
0.15
1.5
0.15
5
2.5
0.13
2.5
0.13
1
4
0.04
4
0.04
MA8-050
5-50 µl
0.5
50
1
0.50
0.7
0.35
25
1.5
0.38
1
0.25
5
3
0.15
2
0.10
MA8-100
10 – 100 µl
0.5
100
1
1.00
0.5
0.50
50
1
0.50
0.5
0.25
10
1.5
0.15
0.75
0.08
MA8-200
20-200 µl
1
200
0.7
1.40
0.25
0.50
100
1
1.00
0.4
0.40
20
1.5
0.30
0.75
0.15
MA8-300
30-300 µl
1
300
0.8
2.40
0.25
0.75
150
1
1.50
0.5
0.75
30
1.5
0.45
0.75
0.23

Accumax VA-FA (Multi 12 Channel)

Cat. No. Volume Range [µl] Increments [µl] Test Volume [µl] Inaccuracy (±) % Inaccuracy (±) µl % Imprecision(±) % Imprecision(±) µl%
MA12-010
0.5-10 µl
0.1
10
1.5
0.15
1.5
0.15
5
2.5
0.13
2.5
0.13
1
4
0.04
4
0.04
MA12-050
5-50 µl
0.5
50
1
0.50
0.7
0.35
25
1.5
0.38
1
0.25
5
3
0.15
2
0.10
MA12-100
10 – 100 µl
0.5
100
1
1.00
0.5
0.50
50
1
0.50
0.5
0.25
10
1.5
0.15
0.75
0.08
MA12-200
20-200 µl
1
200
0.7
1.40
0.25
0.50
100
1
1.00
0.4
0.40
20
1.5
0.30
0.75
0.15
MA12-300
30-300 µl
1
300
0.8
2.40
0.25
0.75
150
1
1.50
0.5
0.75
30
1.5
0.45
0.75
0.23

*10ml pipette doesn’t have tip ejector

Accumax VA-FA
Accumax VA-FA
Accumax VA-FA
Accumax VA-FA
Accumax VA-FA
Accumax VA-FA
Accumax VA-FA
Accumax VA-FA
Accumax VA-FA
Accumax VA-FA
Accumax VA-FA
Accumax VA-FA
Accumax VA-FA
Accumax VA-FA
Accumax VA-FA
Accumax VA-FA

Download

Still have questions? Get in touch with us!

Get a live demo for a better experience of this product and find out why Accumax is the right choice for you.


Inquiry Form